AIPHONE

Home > Support > Software and Document > IX

Software and Document

go to IX page

IX

Software download

Download the latest firmware and applications.

Firmware

  • IX-MV firmware Ver. 2.13
    File name: IX-MV_V213.bin
    File size: 26.9 MB
    Release Date: June. 2018
    Changes:
    • Improved internal functionality. This update does not affect system features.
    History:
    • Ver. 2.12: Improved stability of LCD control.
    • Ver. 2.11: Resolved communication interruption issue when “door release" is activated during a “talk mode".
      Resolved “door release" dysfunction when pressed multiple times during “talk mode".
      Security improvements and bug fixes.
    • Ver. 2.08: Fixed a problem regarding display errors found in firmware Ver2.07. Improved stability of email transmissions. Fixed a problem where the microphone would stay muted after cancelling a call transfer.
    • Ver. 2.07: Operability improvement. Fixed issue: Error when restoring settings file containing NTP Server information on brand new products.
    • Ver. 2.06: When three e-mail addresses were registered, the mail was not sent the second one.
    • Ver. 2.05: Stability improvements on integration with third-party video recording devices.
    • Ver. 2.04: Web server vulnerability patch. Please apply this firmaware update if your IX-MV is used in a network with internet connection.
    • Ver. 2.03: A new SIF interface format has been added for integration with 3rd party products.
    • Ver. 2.01: Corrected wordings related to settings display menu., Feb.2015

  • IX-DA firmware Ver. 2.13
    File name: IX-DA_V213.bin
    File size: 20.2 MB
    Release Date: June. 2018
    Changes:
    • Improved internal functionality. This update does not affect system features.
    History:
    • Ver. 2.12: Improved stability of LCD control.
    • Ver. 2.11: Resolved communication interruption issue when “door release" is activated during a “talk mode".
      Security improvements and bug fixes.
    • Ver. 2.08: Improved stability of email transmissions. Fixed a problem where the microphone would stay muted after cancelling a call transfer.
    • Ver. 2.07: Fixed issue: Error when restoring settings file containing NTP Server information on brand new products.
    • Ver. 2.06: When three e-mail addresses were registered, the mail was not sent the second one.
    • Ver. 2.05: Stability improvements on integration with third-party video recording devices.
    • Ver. 2.04: Web server vulnerability patch. Please apply this firmaware update if your IX-DA is used in a network with internet connection.
    • Ver. 2.03: Added a sound notification announcing the start of conversation from the door station, when a language other than Japanese is selected.
    • Ver. 2.01: Corrected wordings related to settings display menu., Feb.2015

  • IX-BA firmware Ver. 2.13
    File name: IX-BA_V213.bin
    File size: 19.8 MB
    Release Date: June. 2018
    Changes:
    • Improved internal functionality. This update does not affect system features.
    History:
    • Ver. 2.12: Improved stability of LCD control.
    • Ver. 2.11: Resolved communication interruption issue when “door release" is activated during a “talk mode".
      Security improvements and bug fixes.
    • Ver. 2.08: Improved stability of email transmissions. Fixed a problem where the microphone would stay muted after cancelling a call transfer.
    • Ver. 2.07: Fixed issue: Error when restoring settings file containing NTP Server information on brand new products.
    • Ver. 2.06: When three e-mail addresses were registered, the mail was not sent the second one.
    • Ver. 2.05: Stability improvements on integration with third-party video recording devices.
    • Ver. 2.04: Web server vulnerability patch. Please apply this firmaware update if your IX-BA is used in a network with internet connection.
    • Ver. 2.03: Added a sound notification announcing the start of conversation from the door station, when a language other than Japanese is selected.
    • Ver. 2.01: Corrected wordings related to settings display menu., Feb.2015

  • IX-DV firmware Ver. 2.01
    File name: IX-DV_V201.bin
    File size: 26.0 MB
    Release Date: Apr/12/2019
    Applicable to : IX-DV, IX-DVF, IX-DVF-P, IX-DVF-2RA, IX-DVF-RA, IX-DU, IX-DVF-L, IX-BU
    Changes:
    • Fixed a problem that updating device firmware from 1.XX to 2.00 or will reset the device back to its original factory settings, and will delete all the information stored in the device(s). Fixed a problem with IXW-MA whose SIF functionality does not work in case of "change contact SIF" from IX-DA, IX-BA and IX-MV.
    History:
    • Ver. 2.00: Multilingual version. Correction of slight problems.
    • Ver. 1.09: Modified initial value of "Detection Time Range"* and "Detection Management". *Option Input / Relay Output Setting ⇒ Option Input ⇒ Detection Time Range (Setting Tool). Corrected a problem that a registered custom sound source disappers when rebooting after uploading custom sound source from IX support tool.

  • IX-MV7 firmware Ver. 2.02
    File name: IX-MV7_V202.bin
    File size: 83.9 MB
    Release Date: Jun/7/2019
    Applicable to : IX-MV7-B, IX-MV7-HB, IX-MV7-HW, IX-MV7-W
    Changes:
    • DTMF dial tone compatible, minor bug fixes.
    History:
    • Ver. 2.01: Fixes an issue in “Door Release function” not be performed after using about 300 times in case of an output for door release from IX-MV7-*. Updated: Apr/12/2019. Fixed a problem that updating device firmware from 1.XX to 2.00 or will reset the device back to its original factory settings, and will delete all the information stored in the device(s).
    • Ver. 2.00: Multilingual version. Correction of slight problems.
    • Ver. 1.09: Modified initial value of "Detection Time Range"* and "Detection Management". *Option Input / Relay Output Setting ⇒ Option Input ⇒ Detection Time Range (Setting Tool). Corrected a problem that did not recognize the SD card when restarting the terminal with an exFAT formatted SD card.

  • IX-RS firmware Ver. 2.01
    File name: IX-RS_V201.bin
    File size: 24.8 MB
    Release Date: Apr/12/2019
    Applicable to : IX-RS-B, IX-RS-W
    Changes:
    • Fixed a problem that updating device firmware from 1.XX to 2.00 or will reset the device back to its original factory settings, and will delete all the information stored in the device(s). Fixed a problem with IXW-MA whose SIF functionality does not work in case of "change contact SIF" from IX-DA, IX-BA and IX-MV.
    History:
    • Ver. 2.00: Multilingual version. Correction of slight problems.
    • Ver. 1.09: Modified initial value of "Detection Time Range"* and "Detection Management". *Option Input / Relay Output Setting ⇒ Option Input ⇒ Detection Time Range (Setting Tool). Corrected a problem that a registered custom sound source disappers when rebooting after uploading custom sound source from IX support tool.

  • IX-SS-2G firmware Ver. 2.01
    File name: IX-SS-2G_V201.bin
    File size: 24.3 MB
    Release Date: Apr/12/2019
    Applicable to : IX-SS-2G
    Changes:
    • Fixed a problem that updating device firmware from 1.XX to 2.00 or will reset the device back to its original factory settings, and will delete all the information stored in the device(s). Fixed a problem with IXW-MA whose SIF functionality does not work in case of "change contact SIF" from IX-DA, IX-BA and IX-MV.
    History:
    • Ver. 2.00: Multilingual version. Correction of slight problems.
    • Ver. 1.09: Modified initial value of "Detection Time Range"* and "Detection Management". *Option Input / Relay Output Setting ⇒ Option Input ⇒ Detection Time Range (Setting Tool). Corrected a problem that a registered custom sound source disappers when rebooting after uploading custom sound source from IX support tool.

  • IX-SSA firmware Ver. 2.01
    File name: IX-SSA_V201.bin
    File size: 23.8 MB
    Release Date: Apr/12/2019
    Applicable to : IX-SSA, IX-SSA-2RA, IX-SSA-RA
    Changes:
    • Fixed a problem that updating device firmware from 1.XX to 2.00 or will reset the device back to its original factory settings, and will delete all the information stored in the device(s). Fixed a problem with IXW-MA whose SIF functionality does not work in case of "change contact SIF" from IX-DA, IX-BA and IX-MV.
    History:
    • Ver. 2.00: Multilingual version. Correction of slight problems.
    • Ver. 1.09: Modified initial value of "Detection Time Range"* and "Detection Management". *Option Input / Relay Output Setting ⇒Option Input ⇒ Detection Time Range (Setting Tool). Corrected a problem that a registered custom sound source disappers when rebooting after uploading custom sound source from IX support tool.

  • IXW-MA firmware Ver. 2.01
    File name: IXW-MA_V201.bin
    File size: 23.0 MB
    Release Date: Apr/12/2019
    Applicable to : IXW-MA
    Changes:
    • Fixed a problem that updating device firmware from 1.XX to 2.00 or will reset the device back to its original factory settings, and will delete all the information stored in the device(s). Fixed a problem with IXW-MA whose SIF functionality does not work in case of "change contact SIF" from IX-DA, IX-BA and IX-MV.
    History:
    • Ver. 2.00: Multilingual version. Correction of slight problems.
    • Ver. 1.09: Modified initial value of "Detection Time Range"* and "Detection Management". *Option Input / Relay Output Setting ⇒ Option Input ⇒ Detection Time Range (Setting Tool). Corrected a problem that a registered custom sound source disappers when rebooting after uploading custom sound source from IX support tool.

Application

  • Support Tool Ver. 5.0.0.2
    File name: SupportTool_V5002.zip
    File size: 81.8 MB
    Release Date: Jun/7/2019
    Applicable to : IX-DV.M, IX-DVF.M, IX-DVF-P.M, IX-DVF-2RA.M, IX-DVF-RA.M, IX-DU.M, IX-DVF-L.M, IX-BU.M, IX-MV7-B, IX-MV7-HB, IX-MV7-HW, IX-MV7-W, IX-RS-B, IX-RS-W, IX-SS-2G, IX-SSA.M, IX-SSA-2RA.M, IX-SSA-RA.M, IXW-MA
    Changes:
    • Minor bug fixes.
    Note:
    • IX-MV, IX-DA and IX-BA do not support certificate sigining requests (CSR) and SSL certificate uploads. IF these functions are used for IX-MV, IX-DA or IX-BA, the operation will fail and an error message will be dispalyed.
    History:
    • Ver.5.0.0.1: Delete a pop-up "reset the device back to its original factory settings" displayed when firmware updating.
    • Ver.5.0.0.0: Multilingual version. Correction of slight problems.
    • Ver.4.0.0.3: Modified initial value of "Detection Time Range". *Option Input / Relay Output Setting ⇒ Option Input ⇒ Detection Time Range (Setting Tool). Corrected a problem that the clock gains one hour when the date and time is set manually. Corrected a problem that 51 or more scan monitoring can not be registered in "Table View". Corrected writing errors.
    • Ver.4.0.0.2: Default setting for IX-DA video resolution changed to "VGA" in order to inprove compativility with NEW IX system.
    • Ver.4.0.0.1: Major update. Added support for NEW IX intercom stations (IX-DV, IX-DVF, IX-DVF-2RA, IX-DVF-P, IX-DVF-RA, IX-MV7-B, IX-MV7-HB, IX-MV7-HW, IX-MV7-W, IX-RS-B, IX-RS-W, IX-SS-2G, IX-SSA, IX-SSA-2RA, IX-SSA-RA and IXW-MA). Added new setting options used for NEW IX intercom stations. Please download the updated IX Support Tool manual for more details.
    • Ver.2.0.2.1: Windows 10 support added.
    • Ver.2.0.2.0: Corrected wordings related to settings display menu.

  • Supervision Tool Ver. 2.0.0.0
    File name: SupervisionTool_V2000.zip
    File size: 73.9 MB
    Release Date: Feb 2019
    Changes:
    • Multilingual version. Correction of slight problems.
    History:
    • Ver. 1.0.0.0: Released.

Document

Operation manual

Setting Manual

Installation Manual